Portable Hardness Testers

Combined Hardness Tester NOVOTEST T-UD3

The device operates both UCI (Ultrasonic Contact Impedance) and the Leeb (dynamic) probes. Getting benefit from two types of measurements is the ultimate advantage that a portable device can provide.

UCI Hardness Tester NOVOTEST T-U3

The Ultrasonic Contact Impedance (UCI) probe is used for measuring the hardness value of small items, objects with a thin wall, complex form, and to measure the hardness of surface hardened layers.
Built-in camera allows user to picture of testing object and mark tested area with corresponding hardness value.

Leeb Hardness Tester NOVOTEST T-D3

Dynamic (Leeb) probe is used for measuring the hardness of non-ferrous metals, cast iron, coarse-grained materials, massive products etc.
Built-in camera allows user to take a picture of tested object and mark tested area with corresponding hardness value.
Hardness Testers NOVOTEST T-D3 has sealed housing with rubber protective bumper, it is ideal for use in workshop and field conditions with high humidity, dust, etc. Hardness tester has frost-resistant display that allows user to use the device at any seasons and in any climatic zones of the Earth

Combined Hardness Tester NOVOTEST T-UD2

Combined Hardness Tester NOVOTEST T-UD2 is designed for rapid non-destructive hardness testing of:

  • metals and alloys on standardized hardness scales;

  • metals with different properties from steel (for example, non-ferrous metals, alloys, cast iron, etc.) with additional scales for calibration;

  • use the scale of tensile strength (Rm) for determining the tensile strength of carbon steel products pearlitic by automatically converting from Brinell (HB) hardness scale.

 

Device implements 2 methods of testing: rebound (Leeb) and ultrasonic contact impedance (UCI). The combination of both methods allows user to test all range of metal products.

UCI Hardness Tester NOVOTEST T-U2

UCI hardness tester NOVOTEST T-U2 is designed for rapid non-destructive hardness testing of:

  • metals and alloys on standardized international scales of hardness: Rockwell (HRC), Brinell (HB), Vickers (HV);

  • metals with distinctions in properties of steel (e.g., non-ferrous metals, alloys of iron and others.) and using five additional scales for calibration;

  • using a scale of tensile strength (Rm) to determine the tensile strength of carbon steel pearlitic products by automatic recalculation from Brinell (HB) hardness scale

 

Ultrasonic hardness tester T-U2 implements the ultrasonic contact impedance method (UCI)

Leeb Hardness Tester NOVOTEST T-D2

Leeb Hardness Tester NOVOTEST T-D2 is designed for rapid non-destructive hardness testing of various objects.
Leeb Hardness Tester NOVOTEST T-D2 uses dynamic method of hardness testing – Leeb method, standardized according to ASTM A596.
Leeb probe is used for measuring the hardness of non-ferrous metals, cast iron, materials with coarse-grained structure, solid products, etc.